Technical Support Center

Stähle – ADMA Settings for Stähle Robots


Confidentality

All information within this document is strictly confidential and must not be passed to 3rd parties without the prior consent of GeneSys Elektronik GmbH and Stähle.

Introduction to the Stähle integration

This article shows the configuration of the ADMA for using Stähle robots.

ADMA Configuration for AB Dynamics platforms

Connect to the ADMA Web Interface

To access the ADMA web interface for the first time, ensure your PC is configured with an IP address in the 192.168.88.x range. Then, open a browser and enter the following IP address:

Default (Fallback) IP-Address: 192.168.88.30
Default Subnet mask: 255.255.255.0

Configure the CAN interface with the following parameters:

Base ID:100 dec
CAN Baudrate:1000 kBaud
CAN Termination:Off

Data

Shows the Menu of the ADMA Web interface and section 3 - Data .

Configure the CAN data output with the following parameters:

Data rate:100 Hz
Coordinate system:ISO 8855
Data Format Version:v3.3.x

CAN Data Packets

Add all necessary CAN data packets of the ADMAnet data stream by executing Add SD-Robot data packets below the data packet table.

The following data packets will get enabled:

  • Status and Error
  • INS Angle + GNSS-COG
  • INS Position absolute POI1
  • INS Time (UTC)
  • INS Velocity (Horiz.) POI1
  • Miscellaneous POI1
  • Acceleration (Body) POI1
  • Rates (Horiz.)
  • Delta Resultant (Optional)

Parameter

Shows the Menu Data of the ADMA webinterface in which the AB Dynamics platform related kalman filter parameters are configured.

The Parameter page of the ADMA web interface is the only section that must be configured differently for each vehicle. Please ensure you configure the correct mounting offset values between ADMA and GNSS antenna.

Min. velocity for AutoInit:1 m/s
Min. velocity for heading ctrl.:3 m/s
Mounting Offsets (POI 1):Vehicle Center of Mass

Finish Setup and start Measurement

Shows the ADMA Menu with the Menu 8 enabled.

Save the settings to the ADMA and start the measurement.