GeneSys’ own calibration laboratory: High measurement quality and traceability according to ISO 17025

GeneSys not only offers high-performance inertial systems (IMU) but also helps customers make sure that this performance is maintained for many years. Regular calibration of the ADMA systems, traceable to national standards, ensures high measurement quality and traceability. GeneSys is the first DAkkS accredited calibration laboratory according to DIN ISO 17025 for the measurand speed in the range 5m/s to 23m/s.

Why is calibration important?

Each ADMA system is calibrated to GeneSys specifications prior to shipment, but the accuracy of the inertial sensors is subject to natural variations over time. In order to maintain the intended accuracy, it is necessary to calibrate the hardware at regular intervals. Calibration intervals are recommended at one or two years. An inspection sticker with the date of the last calibration is affixed to each device.

Scope of calibration services

The flexible services are tailored to the exact requirements of the customers. With a variety of calibration services, for ADMA systems or systems from other manufacturers, GeneSys can meet all specifications for each type of system or available budget. The GeneSys experts clarify which calibration package is best suited in direct dialog with the customer.

Wide range of services in accordance with ISO 9001 and DIN EN ISO/IEC 17025:2018

Calibration services at GeneSys meet quality standards such as ISO 9001, DIN EN ISO/IEC 17025:2018 as well as IATF 16949. The in-house calibration laboratory is accredited by the DAkkS (German Accreditation Body) for the measured quantities angular velocity, acceleration and speed. GeneSys is thus the first DAkkS accredited calibration laboratory according to DIN ISO 17025 for the measurand velocity in the range 5m/s to 23m/s. With this assignment, the DAkkS confirms that GeneSys competently performs its work in the field of calibrations according to the requirements of internationally valid standards, legal foundations and relevant rules.

Certification according to DIN EN ISO/IEC 17025:2018

GeneSys offers different calibrations:

For the “Turning table calibration”, the unit under test is mounted on a turntable. The angular velocity or the acceleration is calibrated by comparing it with a traceable reference standard.

You can request either a factory calibration or a calibration in the DAkkS-accredited range. Adjustments are exclusive to factory calibrations for GeneSys products. The accredited calibrations are also available for third-party systems.

With “Reference Track Calibration,” the calibration object is permanently mounted in a vehicle. The average speed that is required to pass two reflector strips placed at a known distance on the road is measured. The speed is controlled to the prescribed target speed on a run-up distance.

The calibration of the ADMA systems also always includes an incoming goods inspection to ensure the basic functions of the platform, interfaces and sensors. The GeneSys experts also always carry out a temperature test and a final vehicle dynamics check.

Reasons for calibrating the ADMA and other measuring systems

Compliance with standards

From general quality management systems, such as ISO 9001, to requirements that are specifically geared to test and measurement equipment, such as DIN EN ISO/IEC 17025:2018, there are a number of standards that recommend when calibration is required. By regularly calibrating equipment, the customer ensures that he complies with the applicable measurement standards.

Traceability

Calibration guarantees complete traceability of the measuring equipment. It also ensures that the accuracy of the previously measured data is consistent with future measurements. Failure to perform regular calibration of the measuring equipment can, in the worst case, result in the invalidation of all measurements.

Outage times are expensive

To eliminate the possibility that the measurement data of tests carried out cannot be used by the customer, all measuring equipment should be calibrated at close intervals of one to two years. Calibration is an important part of measurement hardware maintenance. Regular calibration not only saves time and money but also ensures that the customer can meet all project requirements.

Calibration guarantees high measurement quality and traceability.

Find further informations here:

device testing and calibration

Approved for publication. For further information, just give us a call.

In case of publishing/printing, please send a sample copy to:

GeneSys Elektronik GmbH
Dr. Bertold Huber
Maria-und-Georg-Dietrich-Str. 6
77652 Offenburg, Germany

Phone: +49 (0) 781 969279 34
Email:
Fax: +49 (0) 781 969279 11

Add-On LatDev with functional enhancement

What does 16 objects mean in relation to the Add-On LatDev? The...

Integrated NTRIP-Client for ADMA

With the latest ADMA firmware update, we introduce the integrated NTRIP-Client...

Automotive Testing Expo North America, October 22, 23 & 24, 2024

Automotive Testing Expo ist the world's leading trade fair for automotive...