{"id":30185,"date":"2023-06-22T15:15:39","date_gmt":"2023-06-22T13:15:39","guid":{"rendered":"https:\/\/genesys-offenburg.de\/?post_type=smart-docs&#038;p=30185"},"modified":"2023-06-23T09:41:08","modified_gmt":"2023-06-23T07:41:08","slug":"adma-data-analyzer-graphical-interface","status":"publish","type":"smart-docs","link":"https:\/\/genesys-offenburg.de\/zh-hans\/support\/software\/adma-dataview\/adma-data-analyzer-graphical-interface\/","title":{"rendered":"ADMA Data Analyzer Graphical Interface"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Configuration View<\/h2>\n\n\n\n<p>In this view, the measurement data get loaded and the set up for the Plot and the Sample Data Views.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Configuration_Markierungen-1024x602.jpg\" alt=\"\" class=\"wp-image-30186\" width=\"901\" height=\"567\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table support-table is-style-stripes\"><table><thead><tr><th>Number<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><strong>1\ufe0f\u20e3<\/strong><\/td><td>Select the active Plot View to plot selected data channels.<\/td><\/tr><tr><td><strong>2\ufe0f\u20e3<\/strong><\/td><td>Select the amount of plots to display in the selected Plot View.<\/td><\/tr><tr><td><strong>3\ufe0f\u20e3<\/strong><\/td><td>In the data channel overview, channels of the different ADMA files can be selected for plotting and for the Sample Data view. <\/td><\/tr><tr><td><strong>4\ufe0f\u20e3<\/strong><\/td><td>The Error and Warning LED is lightened red or orange, when Errors or Warnings are detected in the loaded ADMA data files. <\/td><\/tr><tr><td><strong>5\ufe0f\u20e3<\/strong><\/td><td>Load Multiple ADMA data files.<\/td><\/tr><tr><td><strong>6\ufe0f\u20e3<\/strong><\/td><td>Delete currenty selected plots.<\/td><\/tr><tr><td><strong>7\ufe0f\u20e3<\/strong><\/td><td>Delete last added ADMA file.<\/td><\/tr><tr><td><strong>8\ufe0f\u20e3<\/strong><\/td><td>Remove all ADMA data files.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Plot View<\/h2>\n\n\n\n<p>This View allows analyzing selected data channels of multiple ADMA systems in parallel. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"602\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Plots_VelStandstillSats_Markierungen-1024x602.jpg\" alt=\"\" class=\"wp-image-30190\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Plots_VelStandstillSats_Markierungen-1024x602.jpg 1024w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Plots_VelStandstillSats_Markierungen-300x176.jpg 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Plots_VelStandstillSats_Markierungen-768x451.jpg 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Plots_VelStandstillSats_Markierungen-1536x902.jpg 1536w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Plots_VelStandstillSats_Markierungen-696x409.jpg 696w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Plots_VelStandstillSats_Markierungen-1068x627.jpg 1068w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Plots_VelStandstillSats_Markierungen.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table support-table is-style-stripes\"><table><thead><tr><th>Number<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><strong>1\ufe0f\u20e3<\/strong><\/td><td>Manual y axis min \/ max value configuration.<\/td><\/tr><tr><td><strong>2\ufe0f\u20e3<\/strong><\/td><td>Set automatic y axis resolution.<\/td><\/tr><tr><td><strong>3\ufe0f\u20e3<\/strong><\/td><td>Contains time information as x-axis. The x-axis of all plots get synchronized. <\/td><\/tr><tr><td><strong>4\ufe0f\u20e3<\/strong><\/td><td>Navigation menue for navigating and zoomin in the single plot views. The view can be set to default and the diagram can be saved \/ copied as different graphic types.<\/td><\/tr><tr><td><strong>5\ufe0f\u20e3<\/strong><\/td><td>Cursors for viewing single sample values and getting the difference. By clicking in between the cursors, the view gets zoomed into the specified area. <\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Sample Data View<\/h2>\n\n\n\n<p>In the Configuration View, data channels can be selected for the Sample Data View. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"602\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1-1024x602.jpg\" alt=\"\" class=\"wp-image-30244\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1-1024x602.jpg 1024w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1-300x176.jpg 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1-768x451.jpg 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1-1536x902.jpg 1536w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1-696x409.jpg 696w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1-1068x627.jpg 1068w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table support-table is-style-stripes\"><table><thead><tr><th>Number<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><strong>1\ufe0f\u20e3<\/strong><\/td><td>The cursor can be moved in the timeline for displaying the current values in the Sample Data table.<\/td><\/tr><tr><td><strong>2\ufe0f\u20e3<\/strong><\/td><td>The Sample Data table shows the current values of the selected data channels. By clicking on specific value cells twice, the value gets copied to the clipboard. <\/td><\/tr><tr><td><strong>3\ufe0f\u20e3<\/strong><\/td><td>Names of the different data records. The naming of the data records within the Data Analyzer can be changed by double clicking the desired name. <\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Relative Trajectory View<\/h2>\n\n\n\n<p>In this view, trajectories of the relative position data can be generated. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"602\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Trajectory_INS_Rel_Marker-1024x602.jpg\" alt=\"\" class=\"wp-image-30247\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Trajectory_INS_Rel_Marker-1024x602.jpg 1024w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Trajectory_INS_Rel_Marker-300x176.jpg 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Trajectory_INS_Rel_Marker-768x451.jpg 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Trajectory_INS_Rel_Marker-1536x902.jpg 1536w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Trajectory_INS_Rel_Marker-696x409.jpg 696w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Trajectory_INS_Rel_Marker-1068x627.jpg 1068w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Trajectory_INS_Rel_Marker.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table support-table is-style-stripes\"><table><thead><tr><th>Number<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><strong>1\ufe0f\u20e3<\/strong><\/td><td>Selection of the relative data to plot. It is possible to select the GNSS raw position data, the INS data in the MRP and all the different POI&#8217;s.<\/td><\/tr><tr><td><strong>2\ufe0f\u20e3<\/strong><\/td><td>Navigation menue for navigating and zoomin in the trajectory view. The view can be set to default and the diagram can be saved \/ copied as different graphic types.<\/td><\/tr><tr><td><strong>3\ufe0f\u20e3<\/strong><\/td><td>Diagram legend.<\/td><\/tr><tr><td><strong>4\ufe0f\u20e3<\/strong><\/td><td>In this function section, displaying samples, only showing data in between the set cursors and displaying the heading as vector at the current cursor position can be activated.<\/td><\/tr><tr><td><strong>5\ufe0f\u20e3<\/strong><\/td><td>Colored Trajcetory plots can be generated. This means single data channels can be visualized as a colored overlay on the trajectory. In the graphic below, the GNSS Mode was overlayed. With this plot it is easy to detect GNSS outages for example.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"601\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1024x601.png\" alt=\"\" class=\"wp-image-30249\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1024x601.png 1024w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-300x176.png 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-768x451.png 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1536x902.png 1536w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-696x409.png 696w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33-1068x627.png 1068w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-33.png 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Absolute Trajectory View<\/h2>\n\n\n\n<p>In this view, trajectories of the absolute position data can be generated. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"602\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-1024x602.jpg\" alt=\"\" class=\"wp-image-30252\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-1024x602.jpg 1024w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-300x176.jpg 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-768x451.jpg 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-1536x902.jpg 1536w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-696x409.jpg 696w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-1068x627.jpg 1068w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table support-table is-style-stripes\"><table><thead><tr><th>Number<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><strong>1\ufe0f\u20e3<\/strong><\/td><td>Selection of the absolute data to plot. It is possible to select the GNSS raw position data, the INS data in the MRP and all the different POI&#8217;s.<\/td><\/tr><tr><td><strong>2\ufe0f\u20e3<\/strong><\/td><td>Navigation menue for navigating and zoomin in the trajectory view. The view can be set to default and the diagram can be saved \/ copied as different graphic types.<\/td><\/tr><tr><td><strong>3\ufe0f\u20e3<\/strong><\/td><td>Diagram legend.<\/td><\/tr><tr><td><strong>4\ufe0f\u20e3<\/strong><\/td><td>In this function section, displaying samples and only showing data in between the set cursors can be activated.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Map View<\/h2>\n\n\n\n<p>In this view, trajectories of the absolute position data can be displayed on open street maps. <\/p>\n\n\n\n<div class=\"wp-block-smartdocs-notice\"><div class=\"smartdocs-block-notice notice-info\"><p><strong>Note<\/strong>: Please care, the open street maps may have offsets because of the map accuracy.<\/p><\/div><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"602\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Map_GeneSys-1024x602.jpg\" alt=\"\" class=\"wp-image-30255\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Map_GeneSys-1024x602.jpg 1024w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Map_GeneSys-300x176.jpg 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Map_GeneSys-768x451.jpg 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Map_GeneSys-1536x902.jpg 1536w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Map_GeneSys-696x409.jpg 696w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Map_GeneSys-1068x627.jpg 1068w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/Map_GeneSys.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">ErrorsWarnings View<\/h2>\n\n\n\n<p>This tab shows errors and warnings in case of occurence.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"567\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-35-1024x567.png\" alt=\"\" class=\"wp-image-30261\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-35-1024x567.png 1024w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-35-300x166.png 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-35-768x425.png 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-35-696x385.png 696w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-35-1068x591.png 1068w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-35.png 1279w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Export View<\/h2>\n\n\n\n<p>This view allows exporting the measurement data as csv, gsda or matlab files. Additionally trajectory data can be saved as kml files. <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"602\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-1024x602.png\" alt=\"\" class=\"wp-image-30257\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-1024x602.png 1024w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-300x176.png 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-768x451.png 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-1536x902.png 1536w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-696x409.png 696w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34-1068x627.png 1068w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2023\/06\/image-34.png 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table support-table is-style-stripes\"><table><thead><tr><th>Number<\/th><th>Description<\/th><\/tr><\/thead><tbody><tr><td><strong>1\ufe0f\u20e3<\/strong><\/td><td>Definition of the folder location to save the exported data in. <\/td><\/tr><tr><td><strong>2\ufe0f\u20e3<\/strong><\/td><td>Selection of the different file formats.<\/td><\/tr><tr><td><strong>3\ufe0f\u20e3<\/strong><\/td><td>It is possible to exort all data or only data in between the blue and black cursor.<\/td><\/tr><tr><td><strong>4\ufe0f\u20e3<\/strong><\/td><td>Definition, which data channels should be exported.<\/td><\/tr><tr><td><strong>5\ufe0f\u20e3<\/strong><\/td><td>Selection of trajectories to save as kml.<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Configuration View In this view, the measurement data g [&hellip;]<\/p>\n","protected":false},"author":148,"featured_media":30266,"template":"","meta":{"_acf_changed":false,"_links_to":"","_links_to_type":0,"footnotes":""},"smartdocs_category":[808,840],"class_list":{"0":"post-30185","1":"smart-docs","2":"type-smart-docs","3":"status-publish","4":"has-post-thumbnail","6":"smartdocs_category-software","7":"smartdocs_category-adma-dataview"},"acf":[],"_links":{"self":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smart-docs\/30185","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smart-docs"}],"about":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/types\/smart-docs"}],"author":[{"embeddable":true,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/users\/148"}],"version-history":[{"count":0,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smart-docs\/30185\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/media\/30266"}],"wp:attachment":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/media?parent=30185"}],"wp:term":[{"taxonomy":"smartdocs_category","embeddable":true,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smartdocs_category?post=30185"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}