{"id":24023,"date":"2022-05-24T13:22:33","date_gmt":"2022-05-24T11:22:33","guid":{"rendered":"https:\/\/genesys-offenburg.de\/?post_type=smart-docs&#038;p=24023"},"modified":"2025-07-29T12:04:31","modified_gmt":"2025-07-29T10:04:31","slug":"rssi-satel","status":"publish","type":"smart-docs","link":"https:\/\/genesys-offenburg.de\/zh-hans\/support\/troubleshooting\/third-party-system-issues\/rssi-satel\/","title":{"rendered":"RSSI value of Satel UHF Modems"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\" id=\"h-rssi-value\">RSSI value<\/h2>\n\n\n\n<p>The RSSI signal threshold defines the minimum power level (dBm) for receiving radio signals of the <a href=\"https:\/\/www.satel.com\/products\/radio-modems\/satelline-easy\/\" target=\"_blank\" rel=\"noreferrer noopener\">Satel UHF radio modems<\/a> GeneSys is using for <a href=\"https:\/\/genesys-offenburg.de\/dgnss-korrekturdaten\/\" target=\"_blank\" rel=\"noreferrer noopener\">DGNSS Correction data<\/a>. Any transmissions below the threshold are ignored by the radio modem.<br>The larger the absolute value, the weaker the received signal.<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">-110 dBm is a weaker signal than -90 dBm<\/pre>\n\n\n\n<p>The value range is defined as follows:<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">-80 to -118 dBm<\/pre>\n\n\n\n<p>Default value:<\/p>\n\n\n\n<pre class=\"wp-block-preformatted\">-115 dBm<\/pre>\n\n\n\n<p>The radio modem shows the RSSI value of the last received message in dBm on the display by default. On top the current value can be requested via SL-Command locally (SL@R?). The value can be shown for 7 seconds after receiving the message. After that time span the value is set to zero again.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-rssi-reference-values\">RSSI Reference Values<\/h2>\n\n\n\n<figure class=\"wp-block-table support-table is-style-stripes\"><table><tbody><tr><td>70 &#8211; 80 dBm<\/td><td>strong signal \/ very good<\/td><\/tr><tr><td>80 &#8211; 94 dBm<\/td><td>satisfying<\/td><\/tr><tr><td>&gt; 94 dBm<\/td><td>sufficient<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-smartdocs-notice\"><div class=\"smartdocs-block-notice notice-info\"><p><strong>Note<\/strong>:<br>Please care that RSSI values are not valid in small rooms because the modems are too close to each other.<\/p><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-sl-command-for-reading-the-signal-strength\">SL Command for Reading the Signal Strength<\/h2>\n\n\n\n<pre class=\"wp-block-preformatted\">SL@R?\\r<\/pre>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-configure-continous-signal-strength-output\">Configure Continous Signal Strength Output<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Open <strong><em>SATEL Configuration Manager<\/em><\/strong><\/li>\n\n\n\n<li>Enable <strong><em>Add RSSI to data <\/em><\/strong><\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"868\" height=\"708\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-111.png\" alt=\"Shows the Satel Configuration Manager for configuring the UHF Radio modem Satelline Easy.\" class=\"wp-image-24024\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-111.png 868w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-111-300x245.png 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-111-768x626.png 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-111-696x568.png 696w\" sizes=\"(max-width: 868px) 100vw, 868px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"935\" height=\"748\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-112.jpg\" alt=\"Shows the help window of the Satel Configuration Manager with some information about the RSSI value.\" class=\"wp-image-24026\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-112.jpg 935w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-112-300x240.jpg 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-112-768x614.jpg 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-112-696x557.jpg 696w\" sizes=\"(max-width: 935px) 100vw, 935px\" \/><\/figure>\n<\/div>\n\n\n<p>Now the signal strength should be sent with every output string as RSSI value. <\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>RSSI value The RSSI signal threshold defines the minimu [&hellip;]<\/p>\n","protected":false},"author":148,"featured_media":30266,"template":"","meta":{"_acf_changed":false,"_links_to":"","_links_to_type":0,"footnotes":""},"smartdocs_category":[807,892,810,858],"class_list":{"0":"post-24023","1":"smart-docs","2":"type-smart-docs","3":"status-publish","4":"has-post-thumbnail","6":"smartdocs_category-auxsystems","7":"smartdocs_category-satel-radio-modem","8":"smartdocs_category-troubleshooting","9":"smartdocs_category-third-party-system-issues"},"acf":[],"_links":{"self":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smart-docs\/24023","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smart-docs"}],"about":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/types\/smart-docs"}],"author":[{"embeddable":true,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/users\/148"}],"version-history":[{"count":3,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smart-docs\/24023\/revisions"}],"predecessor-version":[{"id":40314,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smart-docs\/24023\/revisions\/40314"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/media\/30266"}],"wp:attachment":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/media?parent=24023"}],"wp:term":[{"taxonomy":"smartdocs_category","embeddable":true,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smartdocs_category?post=24023"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}