{"id":22952,"date":"2023-02-09T15:28:55","date_gmt":"2023-02-09T14:28:55","guid":{"rendered":"https:\/\/genesys-offenburg.de\/?post_type=smart-docs&#038;p=22952"},"modified":"2023-06-23T10:06:08","modified_gmt":"2023-06-23T08:06:08","slug":"signal-out","status":"publish","type":"smart-docs","link":"https:\/\/genesys-offenburg.de\/zh-hans\/support\/adma-manual\/adma-configuration\/signal-out\/","title":{"rendered":"Signal Out"},"content":{"rendered":"\n<p>The Signal OUT Ports of the ADMA can be used as Digital output. The following functions can be configured via Webinterface for Signal Out Port:<br>\u2022 Synchronization output to indicate the ADMA&#8217;s sampling time point, thus allowing simple synchronization with peripheral measurement systems which can be triggered externally.<br>\u2022 Frequency output of 1 Hz up to 100 kHz to assist synchronization.<br>\u2022 Status output to indicate a hardware error or status information.<br>\u2022 GNSS-PPS (puls per second) signal.<br>\u2022 Distance output to generate a distance pulse. This is useful for interfacing various electronic devices which do not have a conventional signal available.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Configuration options<\/h2>\n\n\n\n<figure class=\"wp-block-table support-tabel is-style-stripes\"><table><thead><tr><th>MODE<\/th><th>SETTINGS<\/th><\/tr><\/thead><tbody><tr><td>Sync Out<\/td><td>Frequency Edge (Falling \/ Rising)<br>Frequency pulse width (125\u00b5s to 1 msec)<\/td><\/tr><tr><td>Frequency Out<\/td><td>Frequency (1,10,50,100,200,250,400,500,1k,2k,4k,8k,10k,20k,50k,100k Hz)<br>Frequency Edge (Falling \/ Rising)<br>Frequency pulse width (125 \u00b5s to 1 ms)<\/td><\/tr><tr><td>Status Out<\/td><td>Status Polarity Active (High \/ Low)<br>Status Type (Error)<\/td><\/tr><tr><td>GNSS PPS Out<\/td><td>Frequency Edge (Falling \/ Rising)<br>Frequency pulse width (125 \u00b5s to 1 msec)<\/td><\/tr><tr><td>Distance Out<\/td><td>Pulses Distance Travelled (1 cm\/pulse to 100 cm\/pulse)<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>The Signal OUT Ports of the ADMA can be used as Digital [&hellip;]<\/p>\n","protected":false},"author":148,"featured_media":30266,"template":"","meta":{"_acf_changed":false,"_links_to":"","_links_to_type":0,"footnotes":""},"smartdocs_category":[809,844],"class_list":{"0":"post-22952","1":"smart-docs","2":"type-smart-docs","3":"status-publish","4":"has-post-thumbnail","6":"smartdocs_category-adma-manual","7":"smartdocs_category-adma-configuration"},"acf":[],"_links":{"self":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smart-docs\/22952","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smart-docs"}],"about":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/types\/smart-docs"}],"author":[{"embeddable":true,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/users\/148"}],"version-history":[{"count":0,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smart-docs\/22952\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/media\/30266"}],"wp:attachment":[{"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/media?parent=22952"}],"wp:term":[{"taxonomy":"smartdocs_category","embeddable":true,"href":"https:\/\/genesys-offenburg.de\/zh-hans\/wp-json\/wp\/v2\/smartdocs_category?post=22952"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}