Connecting to the SensorX


For connecting to the SensorX the SensorX Client Software is needed. It is part of the GeneSys Software Suite, which you can download at the download section of the website.

Connecting via static ip address

Before connecting, you need to adapt the ip address of your PC network interface. For that, please execute the following steps:

  1. Open Network Connections by clicking the Start button . Then click Control Panel. Open Network and Sharing Center click View network connections.
  2. Right-click the connection that you want to change, then click Properties . If you’re asked for an administrator password or confirmation, enter the password or provide the required confirmation.
  3. Click the Networking tab. Under This connection uses the following items, choose Internet Protocol Version 4 (TCP/IPv4), then choose Properties.
  4. To specify an IP address, click Use the following IP address, and then, in the IP address, Subnet mask, and type in the following IP address settings:
IP-Address:192.168.88.xxx
Subnet mask:255.255.255.0

Note: The default ip address of the SensorX is the 192.168.88.24. (X is the 24 th letter in the alphabet)

Follow this Screenshot Sequence to configure the ip address of your pc according to your ADMA / SensorX.

Now you can connect by opening the SensorX Client Software. The default ip is automatically typed in, you only need to click connect.

Shows the login screen of the SensorX Software Client in which the ip address of your SensorX device has to be entered.

Connecting via DHCP

For connecting when DHCP is enabled simply press the button at the SensorX and check the ip address the system got from the DHCP server. Use this ip address in the SensorX client and connect.

Shows the Display and its button of the SensorX.