Improperly secured components or poorly routed cables can interfere with vehicle operation and endanger people. Therefore, observe the following instructions:
- Secure mounting: Secure SensorX, the camera, microphone, and accessories to prevent them from coming loose, shifting, or falling. Take strong braking and evasive maneuvers into account.
- Keep safety areas clear: Do not install components within the deployment area of airbags. The driver’s field of view, controls, and pedal area must remain unobstructed.
- Cable routing: Secure cables to prevent them from shifting, becoming pinched, or chafing. They must not interfere with vehicle operation or with entering and exiting the vehicle.
- Suction cup and adhesive mounts: Follow the mounting manufacturer’s specifications regarding the surface, cleaning, temperature, and load. Use an additional safety restraint if detachment could endanger people or interfere with vehicle operation.
- Check before driving: Verify that all components, mounts, and cables are securely installed. Do not begin a test drive if any mounting components are loose or damaged.
- Work only while stationary: Perform installation, alignment, and configuration only when the vehicle is stationary and secured against unintended movement. The driver must not operate the system while driving.
Electrical Supply and Safe Commissioning
Operate SensorX only with a 9–32 V DC power supply. The operating temperature range is −10 to +50 °C for the base unit and 0 to +50 °C for the camera and microphone. Observe the operating limits of each connected component.
Before connecting the device, verify the supply voltage, polarity and connector pin assignment. Use connection cables and accessories approved for SensorX. Make electrical connections with the power supply switched off and check that all connections are correct and secure before switching on.
Install the system in a dry location, protect it from moisture and condensation, and ensure adequate heat dissipation. Do not cover the cooling surfaces of the base unit.
Do not operate the system if the device or its cables are visibly damaged. If unusual heat develops during operation, disconnect the power supply and have the cause investigated before using the system again.

Environmental Protection

Electrical and electronic equipment must be collected separately from unsorted municipal waste. The crossed-out wheeled bin symbol indicates that the equipment must not be disposed of with household waste.
Before handing over waste equipment, remove any waste batteries that are not enclosed by the equipment and any lamps that can be removed without damage, where applicable.
You are responsible for deleting any personal data stored on the equipment before disposal.
Return and disposal: GeneSys Elektronik GmbH / Maria-und-Georg-Dietrich-Str. 6 / D-77652 Offenburg / Germany. For further information, contact GeneSys Support.
Safe Use of Communication Interfaces and Detection Outputs
Before connecting SensorX to a vehicle network or external equipment, verify connector pin assignments, electrical compatibility and interface settings. Ensure that transmitted CAN messages do not interfere with vehicle functions.
Validate detection settings and output signals before each measurement series and after configuration or sensor-position changes. Account for false, missed or delayed detections when integrating outputs into automated test sequences.
SensorX outputs may be used in automated test sequences, provided that independent safety measures prevent incorrect, missing or delayed outputs from causing hazardous actions. SensorX must not be relied upon to perform safety-related control functions. The system integrator is responsible for assessing and validating the overall test setup.