{"id":38634,"date":"2025-01-27T15:10:42","date_gmt":"2025-01-27T14:10:42","guid":{"rendered":"https:\/\/genesys-offenburg.de\/?post_type=smart-docs&#038;p=38634"},"modified":"2025-01-29T19:30:22","modified_gmt":"2025-01-29T18:30:22","slug":"adma-data-output","status":"publish","type":"smart-docs","link":"https:\/\/genesys-offenburg.de\/en\/support\/tec-doc\/data-output\/adma-data-output\/","title":{"rendered":"ADMA &#8211; Data Streams and Output settings"},"content":{"rendered":"\n<p>The ADMA system offers various data streams that can be output through both CAN and Ethernet interfaces. Some streams are exclusively available via Ethernet and not through CAN.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-data-stream-overview\">Data Stream overview<\/h2>\n\n\n\n<p>The table below gives an overview of all available data streams and their output options:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Data stream<\/th><th>Ethernet<\/th><th>CAN<\/th><th>Serial<\/th><th>License required<\/th><\/tr><\/thead><tbody><tr><td>ADMAnet<\/td><td>\u2705<\/td><td>\u2705<\/td><td>\u274c<\/td><td><\/td><\/tr><tr><td>Steering and driving robot <\/td><td>\u2705<\/td><td>\u274c<\/td><td>\u274c<\/td><td><\/td><\/tr><tr><td>GNSS Raw data<\/td><td>\u2705<\/td><td>\u274c<\/td><td>\u2705<\/td><td>(\ud83d\udd12) Can be sent via serial interface without license.<\/td><\/tr><tr><td>Add-On Braking<\/td><td>\u2705<\/td><td>\u2705<\/td><td>\u274c<\/td><td>\ud83d\udd12<\/td><\/tr><tr><td>Add-On Delta 1:1<\/td><td>\u2705<\/td><td>\u2705<\/td><td>\u274c<\/td><td>\ud83d\udd12<\/td><\/tr><tr><td>Add-On Delta 1:5<\/td><td>\u2705<\/td><td>\u274c<\/td><td>\u274c<\/td><td>\ud83d\udd12<\/td><\/tr><tr><td>Add-On LatDev<\/td><td>\u2705<\/td><td>\u2705<\/td><td>\u274c<\/td><td>\ud83d\udd12<\/td><\/tr><tr><td>Target Ego<\/td><td>\u2705<\/td><td>\u274c<\/td><td>\u274c<\/td><td><\/td><\/tr><tr><td>GPRMC<\/td><td>\u274c<\/td><td>\u274c<\/td><td>\u2705<\/td><td><\/td><\/tr><tr><td>GPGGA<\/td><td>\u274c<\/td><td>\u274c<\/td><td>\u2705<\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div class=\"wp-block-smartdocs-notice\"><div class=\"smartdocs-block-notice notice-info\"><p><strong>Note<\/strong>: All data streams (except for the serial data streams) can be visualized and recorded in the <a href=\"https:\/\/genesys-offenburg.de\/adma-data-logger-software\/\" target=\"_blank\" rel=\"noreferrer noopener\">ADMA Data Logger<\/a>.  <\/p><\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-ethernet-udp-output-principle\">Ethernet (UDP) Output principle<\/h2>\n\n\n\n<p>The following image shows a schematic of two ADMA systems in the same network, that output the same data streams to the same receiving device (DAQ). <\/p>\n\n\n\n<p>The DAQ (Data Acquisition System) filters incoming UDP data packets by using source IP addresses and source ports. The source IP address identifies the system from which the data packet originates, while the source port determines the specific data stream. This allows the DAQ to correctly route the packets to the appropriate data stream reception container.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/Datenstrom-Sheme_v2.4-1024x576.jpg\" alt=\"Shows a technical scheme of the ADMA UDP data streams, that are output to the ip address of a laptop. The data streams are getting filtered by source ip and source port and put in different boxes. \" class=\"wp-image-38805\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/Datenstrom-Sheme_v2.4-1024x576.jpg 1024w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/Datenstrom-Sheme_v2.4-300x169.jpg 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/Datenstrom-Sheme_v2.4-768x432.jpg 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/Datenstrom-Sheme_v2.4-1536x864.jpg 1536w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/Datenstrom-Sheme_v2.4-696x392.jpg 696w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/Datenstrom-Sheme_v2.4-1068x601.jpg 1068w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/Datenstrom-Sheme_v2.4-1320x743.jpg 1320w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/Datenstrom-Sheme_v2.4.jpg 1920w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-configuration-of-the-standard-ethernet-data-streams\">Configuration of the standard ethernet data streams<\/h2>\n\n\n\n<p>The settings for all license-free data streams can be found in the ADMA web interface under Menu <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-pale-cyan-blue-color\">3 &#8211; Data<\/mark>. Here, they can be activated and configured.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"810\" height=\"111\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-58.png\" alt=\"\" class=\"wp-image-38681\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-58.png 810w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-58-300x41.png 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-58-768x105.png 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-58-696x95.png 696w\" sizes=\"(max-width: 810px) 100vw, 810px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-admanet\">ADMAnet<\/h3>\n\n\n\n<p>The ADMAnet data stream can be sent via unicast, what means directly to a speficif ip address.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"528\" height=\"205\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-53.png\" alt=\"\" class=\"wp-image-38647\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-53.png 528w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-53-300x116.png 300w\" sizes=\"(max-width: 528px) 100vw, 528px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"960\" height=\"439\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Direct-IP-1.jpg\" alt=\"\" class=\"wp-image-38661\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Direct-IP-1.jpg 960w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Direct-IP-1-300x137.jpg 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Direct-IP-1-768x351.jpg 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Direct-IP-1-696x318.jpg 696w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p>It is also possible to send it as broadcast, which results in a significantly higher network load.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"523\" height=\"205\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-54.png\" alt=\"\" class=\"wp-image-38650\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-54.png 523w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-54-300x118.png 300w\" sizes=\"(max-width: 523px) 100vw, 523px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"960\" height=\"540\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Broadcast.jpg\" alt=\"\" class=\"wp-image-38664\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Broadcast.jpg 960w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Broadcast-300x169.jpg 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Broadcast-768x432.jpg 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Broadcast-696x392.jpg 696w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p>Additionally it is possible to send the ADMAnet data stream via multiple unicasts to up to <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-pale-cyan-blue-color\">five <\/mark>ip-addresses. This can be achieved by increasing the <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-pale-cyan-blue-color\">Data Streams<\/mark> setting.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"525\" height=\"377\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-66.png\" alt=\"\" class=\"wp-image-38718\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-66.png 525w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-66-300x215.png 300w\" sizes=\"(max-width: 525px) 100vw, 525px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"960\" height=\"540\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Multiple-Direct-IP.jpg\" alt=\"\" class=\"wp-image-38667\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Multiple-Direct-IP.jpg 960w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Multiple-Direct-IP-300x169.jpg 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Multiple-Direct-IP-768x432.jpg 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/UDP-Types-Multiple-Direct-IP-696x392.jpg 696w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-steering-and-driving-robot-data-output\">Steering and driving robot data output<\/h3>\n\n\n\n<p>The robot data stream is used to provide position, movement and angle information to the robot system, so the robot is able to drive \/ steer the vehicle.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"530\" height=\"210\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-56.png\" alt=\"\" class=\"wp-image-38673\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-56.png 530w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-56-300x119.png 300w\" sizes=\"(max-width: 530px) 100vw, 530px\" \/><\/figure>\n\n\n\n<p>The robot data stream can be output through any Ethernet interface provided by your ADMA. The protocol must be selected based on the type of robot you are using. All POIs (Points of Interest) can be chosen as the reference point.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-gnss-raw-data-output\">GNSS raw data output<\/h3>\n\n\n\n<p>The GNSS raw data stream is used for post processing or for later analysis of the GNSS signals. <\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"523\" height=\"143\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-57.png\" alt=\"\" class=\"wp-image-38678\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-57.png 523w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-57-300x82.png 300w\" sizes=\"(max-width: 523px) 100vw, 523px\" \/><\/figure>\n\n\n\n<p>It can be output via Ethernet or via serial interfaces. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-configuration-of-the-add-on-ethernet-data-streams\">Configuration of the Add-On ethernet data streams<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"802\" height=\"116\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-59.png\" alt=\"\" class=\"wp-image-38684\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-59.png 802w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-59-300x43.png 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-59-768x111.png 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-59-696x101.png 696w\" sizes=\"(max-width: 802px) 100vw, 802px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-add-on-braking\">Add-On Braking<\/h3>\n\n\n\n<p>The Add-On Braking data stream can be activated at <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-pale-cyan-blue-color\">Add-Ons \/ Braking<\/mark>. <\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"529\" height=\"283\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-60.png\" alt=\"\" class=\"wp-image-38687\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-60.png 529w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-60-300x160.png 300w\" sizes=\"(max-width: 529px) 100vw, 529px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-add-on-delta-1-1\">Add-On Delta 1:1<\/h3>\n\n\n\n<p>The Add-On Delta 1:1 data stream can be activated at the upper configuration page of <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-pale-cyan-blue-color\">Add-On \/ Delta 1:5 \/ Hunter Configuration<\/mark> of the ADMA webinterface. It is possible to select between the available ethernet interfaces.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"527\" height=\"250\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-61.png\" alt=\"\" class=\"wp-image-38692\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-61.png 527w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-61-300x142.png 300w\" sizes=\"(max-width: 527px) 100vw, 527px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-add-on-delta-1-5\">Add-On Delta 1:5<\/h3>\n\n\n\n<p>The Add-On Delta 1:5 data stream can be activated at the lower configuration page of <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-pale-cyan-blue-color\">Add-On \/ Delta 1:5 \/ Hunter Configuration<\/mark> of the ADMA webinterface. It is possible to select between the available ethernet interfaces.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"528\" height=\"231\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-62.png\" alt=\"\" class=\"wp-image-38696\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-62.png 528w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-62-300x131.png 300w\" sizes=\"(max-width: 528px) 100vw, 528px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-add-on-latdev\">Add-On LatDev<\/h3>\n\n\n\n<p>The Add-On LatDev data stream can be activated at <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-pale-cyan-blue-color\">Add-Ons \/ Lateral-Deviation <\/mark>of the ADMA webinterface. It is possible to select between the available ethernet interfaces.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"525\" height=\"246\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-63.png\" alt=\"\" class=\"wp-image-38702\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-63.png 525w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-63-300x141.png 300w\" sizes=\"(max-width: 525px) 100vw, 525px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-configuration-of-the-can-data-output\">Configuration of the CAN data output<\/h2>\n\n\n\n<p>The CAN data output can be activated at <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-pale-cyan-blue-color\">3 &#8211; Data \/ CAN data packets<\/mark> in the ADMA webinterface.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"535\" height=\"137\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-64.png\" alt=\"\" class=\"wp-image-38708\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-64.png 535w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-64-300x77.png 300w\" sizes=\"(max-width: 535px) 100vw, 535px\" \/><\/figure>\n\n\n\n<p>When activated, you have to select all data packets you want to output. This can be done in the following table. <\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"521\" height=\"378\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-65.png\" alt=\"\" class=\"wp-image-38712\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-65.png 521w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2025\/01\/image-65-300x218.png 300w\" sizes=\"(max-width: 521px) 100vw, 521px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-smartdocs-notice\"><div class=\"smartdocs-block-notice notice-warn\"><p><strong>Note<\/strong>: The CAN data bus has bandwidth limits. Because of that you can only select a specific amount of data packets (depending on the selected update rate). Find more detailes at the article <a href=\"https:\/\/genesys-offenburg.de\/support\/troubleshooting\/output-issues\/can-output-issues\/\" target=\"_blank\" rel=\"noreferrer noopener\">CAN output issues<\/a>.<\/p><\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The ADMA system offers various data streams that can be output through both CAN and Ethernet interfaces. Some streams are exclusively available via Ethernet and not through CAN. Data Stream overview The table below gives an overview of all available data streams and their output options: Data stream Ethernet CAN Serial License required ADMAnet \u2705 [&hellip;]<\/p>\n","protected":false},"author":148,"featured_media":0,"template":"","meta":{"_acf_changed":false,"_links_to":"","_links_to_type":0,"footnotes":""},"smartdocs_category":[809,844,847,878,882],"class_list":{"0":"post-38634","1":"smart-docs","2":"type-smart-docs","3":"status-publish","5":"smartdocs_category-adma-manual","6":"smartdocs_category-adma-configuration","7":"smartdocs_category-measurement-data","8":"smartdocs_category-tec-doc","9":"smartdocs_category-data-output"},"acf":[],"_links":{"self":[{"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/smart-docs\/38634","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/smart-docs"}],"about":[{"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/types\/smart-docs"}],"author":[{"embeddable":true,"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/users\/148"}],"version-history":[{"count":3,"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/smart-docs\/38634\/revisions"}],"predecessor-version":[{"id":38809,"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/smart-docs\/38634\/revisions\/38809"}],"wp:attachment":[{"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/media?parent=38634"}],"wp:term":[{"taxonomy":"smartdocs_category","embeddable":true,"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/smartdocs_category?post=38634"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}