{"id":24167,"date":"2022-05-25T11:56:34","date_gmt":"2022-05-25T09:56:34","guid":{"rendered":"https:\/\/genesys-offenburg.de\/?post_type=smart-docs&#038;p=24167"},"modified":"2024-12-19T11:09:13","modified_gmt":"2024-12-19T10:09:13","slug":"technical-paper-adma-pp-performance-indicators","status":"publish","type":"smart-docs","link":"https:\/\/genesys-offenburg.de\/en\/support\/technical-papers\/technical-paper-adma-pp-performance-indicators\/","title":{"rendered":"Technical Paper &#8211; ADMA-PP Performance Indicators"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" width=\"960\" height=\"280\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/Thumbnail_PP-Performance_v1.3.png\" alt=\"\" class=\"wp-image-24173\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/Thumbnail_PP-Performance_v1.3.png 960w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/Thumbnail_PP-Performance_v1.3-300x88.png 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/Thumbnail_PP-Performance_v1.3-768x224.png 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/Thumbnail_PP-Performance_v1.3-696x203.png 696w\" sizes=\"(max-width: 960px) 100vw, 960px\" \/><\/figure>\n<\/div>\n\n\n<p>In this test scenario, measurement data from an ADMA-G Pro+ with correction data was used as a<br>reference for a 15 km highway trip. In comparison to this ADMA, different GNSS outages were now<br>considered with the duration of 1 minute, 2 minutes and 5 minutes. For each comparison, the ADMA<br>online data and the offline ADMA-PP combined data were compared with the reference, once without<br>external speed signal and once with.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img decoding=\"async\" width=\"1024\" height=\"637\" src=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-128-1024x637.jpg\" alt=\"\" class=\"wp-image-24170\" srcset=\"https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-128-1024x637.jpg 1024w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-128-300x187.jpg 300w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-128-768x478.jpg 768w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-128-696x433.jpg 696w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-128-1068x664.jpg 1068w, https:\/\/genesys-offenburg.de\/wp-content\/uploads\/2022\/05\/image-128.jpg 1386w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-smartdocs-notice\"><div class=\"smartdocs-block-notice notice-info\"><p><strong>Note<\/strong>: The drift effects in case of GNSS failure depend very much on the length of the outage and on<br>the strength and amount of dynamic stimulations. This means that this document is only an example<br>analysis for the circumstances given here. The ADMA and the ADMA-PP may react completely different<br>to other conditions.<br>GNSS outages in the online ADMA data cause a drift effect of the position. The better the IMU of the<br>system, the less drift will occur. At the end of the outage, the signal \u201cjumps\u201d back to the true position.<br>In contrast to this, the ADMA-PP signal contains no position \u201cjumps\u201d. Instead, an position offset is<br>building up to a maximum in mid of the GNSS outage.<br>For further information to the ADMA-PP, please refer to the ADMA-PP Whitepaper.<\/p><\/div><\/div>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-group genesys-cta-s\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"forminator-guttenberg\"><form id=\"forminator-module-37449\" class=\"forminator-custom-form forminator-custom-form-37449\" method=\"post\" data-forminator-render=\"0\" data-uid=\"69e4d923ec2b5\"><div role=\"alert\" aria-live=\"polite\" class=\"forminator-response-message forminator-error\" aria-hidden=\"true\"><\/div><\/form><\/div>\n<\/div><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>In this test scenario, measurement data from an ADMA-G Pro+ with correction data was used as areference for a 15 km highway trip. In comparison to this ADMA, different GNSS outages were nowconsidered with the duration of 1 minute, 2 minutes and 5 minutes. For each comparison, the ADMAonline data and the offline ADMA-PP combined [&hellip;]<\/p>\n","protected":false},"author":148,"featured_media":30266,"template":"","meta":{"_acf_changed":false,"_links_to":"","_links_to_type":0,"footnotes":""},"smartdocs_category":[872],"class_list":{"0":"post-24167","1":"smart-docs","2":"type-smart-docs","3":"status-publish","4":"has-post-thumbnail","6":"smartdocs_category-technical-papers"},"acf":[],"_links":{"self":[{"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/smart-docs\/24167","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/smart-docs"}],"about":[{"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/types\/smart-docs"}],"author":[{"embeddable":true,"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/users\/148"}],"version-history":[{"count":2,"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/smart-docs\/24167\/revisions"}],"predecessor-version":[{"id":37495,"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/smart-docs\/24167\/revisions\/37495"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/media\/30266"}],"wp:attachment":[{"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/media?parent=24167"}],"wp:term":[{"taxonomy":"smartdocs_category","embeddable":true,"href":"https:\/\/genesys-offenburg.de\/en\/wp-json\/wp\/v2\/smartdocs_category?post=24167"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}